Example Pump Controls in InfoSewer and H2OMap Sewer

Image
Example Pump Controls in InfoSewer and H2OMap Sewer Five ways to control the pump by controls in InfoSewerH20Map Sewer. Here are a few examples and important features of the various InfoSewer Pump Controls. A pump in InfoSewerH20Map Sewer uses a Newton-Raphson iteration process for 50 iterations or until the successive iterations between pump flows are 0.001 cfs. Pump volume – control the pump by the pump volume (cubic feet or cubic meters). The on and off settings, pump curve and the iteration process applying to pumps are the controlling simulation features. By Level– control the pump by the pump level or depth ( feet or meters). The on and off settings, pump curve and the iteration process applying to pumps are the controlling simulation features. By Discharge – control the pump by the pump pattern in flow units. The pump pattern (discharge), pump curve and the iteration process applying to pumps are the controlling simulation features. The pump speed adjusts to main the pump pattern. …

Innovyze InfoSewer vs InfoSWMM and H2OMap SWMM vs H2OMap Sewer

Image
Innovyze InfoSewer vs InfoSWMM and H2OMap SWMM vs H2OMap Sewer A short comparison of the features in infoSWMM and infoSewer. Many of the same rows apply to H2OMap SWMM and H2OMap Sewer. Feature ClassFeatureInfoSewerInfoSWMMBase FunctionalityConservative Solution as an optionPublic domain engineCalibrate model to flow dataCalibration DataModels siphonsInfers missing invertsValidation toolsDWF AllocatorModels flow attenuationRDII flow data processingFacility ManagerBatch Simulation